General Water Treatment Q & A

Which type of filter do I need?

Nearly every water source can be improved with the right water filtration system. Even if your water is under tight federal oversight, it contains substances that cause unpleasant taste and odors.

Whole House vs Undersink Filtration

Whole House Water Treatment Options




What's in my water?

If you're on city water, you can easily find where your water comes from and what's in it by looking at the Consumer Confidence Report (CCR). Most municipalities mail this each year to you by July 1st.  They can also be found online at the EPA database here.

EPA Consumer Confidence Reports

If you're on a private well, you should obtain a water analysis from a certified laboratory. Collect a sample of your water and fill out the test forms, ship it to the lab and receive an in-depth report that has all of your results compared side-by-side with National EPA Standards.


Gravity feed water system



What treatment system do I need?

It's easier to find the correct treatment system once you know what's in your water. 


Where should a pump be installed?

A booster pump is most commonly installed in a reverse osmosis water system between the stage 1 sediment filter and the stage 2 carbon filter. US booster pump manufacturer Aquatec recommends that the pump should always be mounted prior to the carbon pre-filter to prevent carbon particles from entering the pump chambers and possibly causing clogging.

Most pumps can be mounted horizontaly or vertically. However, if vertical mounting is needed, make sure to place the pumphead facing up to avoid performance reduction. If the pumphead is mounted upside down, air entrapment may reduce the operational performance by up to 15%.


Can the pump run continously 24/7?

This will depend on the model of the pump. The Aquatec CDP series pumps are designed for continuous duty. If used for intermittent duty cycle. Make sure that “off” periods are greater than 60 seconds. 

An RO design with an auto shutoff valve should shut off the system when it reaches appromimately 60% of the boosted line pressure (e.g., a boosted pressure of 70 PSI will = a maximum ro water tank pressure of 42 PSI). RO's with a high-pressure switch (deactivated at 40, 60 or 80 PSI) cuts off power to the pump when the pressurized water storage tank has reached the capacity.


What boosted pressure can I expect?

Most Aquatec boost pumps are designed to limit the maximum output pressure to 110 psi, to protect the membrane and other components from damage. The normal operating pressure as measured after the pump, and before the membrane, will be approximately 80 psi. The flow rate of the 6800 series pump during operation is about 500 ml/min. The 8800 is double that flow. If these parameters are not being met, please check the following:

1.Is the pump properly sized to handle the production rate of the membrane, plus the brine flow allowed by the restrictor (usually 4 or 5 times the permeate production)?

2. Is the system receiving adequate feed water? The pump’s inlet chamber must be flooded to prevent performance robbing air ingestion into the compression chambers.

3. Debris entering the pump, such as residue from an activated carbon filter improperly located on the inlet side of the pump, may restrict the pumping operation. 


What flow rates can I expect from the RO faucet?

RO faucet flow rateFlow rate from your RO drinking water faucet should be approximately 0.5 GPM if the system is operating properly. Most RO faucets will flow at approximately 1 GPM. The loss of flow from the post coconut shell carbon filter, tubing length, etc. can drop you to the ½ GPM range. 


When should the pump be serviced?

Every Year: Check system against operating standards.

Every 2-3 Years: Replace diaphragm and check against operating standards.


References:

  1. WECO HYDRA RO Manual. 2017.
  2. Horner, Allan. “Love Plumbing & Remodel of Bellevue & Bothell WA, Terry Love.” Love Plumbing & Remodel of Bellevue & Bothell WA, Terry Love, 12 Sept. 2012, terrylove.com
  3. FILMTEC.  DOW FILMTEC Membranes, www.dow.com.
  4. “TROUBLE SHOOTING GUIDE FOR R.O. BOOST PUMP SYSTEMS .” Aquatec, www.aquatec.com.
  5. “OPERATIONAL AND INSTALLATION GUIDELINES “CDP” SERIES BOOSTER PUMP .” Aquatec, www.aquatec.com.