- 4000 GPD Commercial Wall Mount Reverse Osmosis Systems offer high production capacities and are fully equipped with a computer controller, TDS monitor, multistage booster pump, low energy membranes and a sediment filter mounted on a corrosion - resistant, powder - coated aluminum frame.
- RO filtration system removes sediment, chlorine, chloramine, arsenic, nitrate, sodium, heavy metals, TDS, chromium, fluoride, mercury, radon, benzene, lead and more contaminants.
- Water pressure sensors and booster pumps keep filtration system functioning at maximum capacity.
- CCMG-0948 Backwashing Filter with Catalytic Activated Carbon and KDF-85® Media Guard for pre-filtering chlorinated water.
- 500 Gallon atmospheric water tank (white) for storing potable water.
- Corona discharge ozone system for disinfecting water.
- CALC-0948 Backwashing Filter with Calcite for pH Neutralization.
- Water pressure booster pump designed for domestic and commercial water supply, pressure boosting, irrigation and dewatering applications. Integrated speed controller works to keep a constant pressure in the pipe system.
WECO Felicity Commercial Drinking Water Purification Package
Felicity combines filtration, reverse osmosis, storage, post-treatment and pressurization equipment into one package. Commercial grade wall mount ro system delivers 4000 gallons of purified drinking water a day at a 98.9% nominal rejection. RO comes standard with a computer controller, TDS monitor, multistage booster pump, low energy membranes and a sediment filter mounted on a corrosion - resistant, powder - coated aluminum frame. EZMount™ two - piece wall mounting system can be converted into a floor standing unit with an optional mobile stand.
Filtration starts with a WECO CCMG-0948 Backwashing filter with catalytic granular activated carbon (GAC) plus a KDF-85 Media Guard, which is a high-performance Point-Of-Entry (POE) filter designed to remove chlorine, chloramine and rotten egg odors caused by hydrogen sulfide from water supplies. Ferrous iron along with potentially harmful metals such as zinc, cadmium and copper are oxidized and rendered non-reactive by catalytic reactions. Chlorine disinfection process can create cancer-causing byproducts in the water. These carcinogens, called THMs, are removed by the catalytic charcoal filter. The carbon filter also remove organic contaminants like herbicides, insecticides and industrial chemicals that seep into groundwater.
WECO commercial reverse osmosis system uses two stages of water filtration to create pure drinking water, ideal for residential use, medical offices, laboratories, schools, aquariums and hydroponic growing operations. The process starts by removing tiny particles like rust, silt, and insect parts. This protects your family and prevents the filtration systems from clogging. The next step involves the reverse osmosis (RO) process. Here water is “squeezed” through a special loe energy membrane. Heavy metals, like lead and mercury, are removed while purified water passes through. The RO process also removes salts, fluoride, radon, and benzene. The RO makes refreshing water the whole family will enjoy. Automatic Goulds® Multi - Stage Booster Pump connected with pressure sensors keep the system operating in optimal condition. We recommend installation by a licensed plumber to ensure adherence to all local codes.
Depending upon your specific water chemistry, you may need RO pre-treatment. Please consult with one of our WQA certified water specialists if your TDS levels exceed 1000 ppm, have hard water or iron staining issues or high silica content in water.
Booster Pump for Prefect Water Pressure
The CMBE Booster is designed for domestic and commercial water supply, pressure boosting, irrigation and dewatering applications.
The CMBE series uses energy efficient, permanent magnet motor technology, which provides unmatched reliability, quiet operation, and energy savings.
Thanks to the integrated speed controller, the CMBE keeps a constant pressure in the pipe system. A pressure sensor monitoring discharge pressure will signal to the speed controller to change the motor speed to adapt the performance to the new situation.
Standard Features
Membrane Elements
Membrane Housings
Filter Cartridge
Filter Housings
Flow Control
Brackets and Clips
RO Specifications
Model | System Capacity | Membrane Elements | Standard Recovery | Nominal TDS Rejection | Dimensions L x W x H in (cm) | Shipping Weight lbs (kg) | ||
---|---|---|---|---|---|---|---|---|
GPD | LPD | Size | Quantity | |||||
JT-4000 | 4000 | 1,892 | 4040 | 5 | 50% | 98.5% | 12 x 15 x 34(31 x 38 x 86) | 70 (32) |
UV Disinfection System Specifications
Model | System Capacity | In/Out | System Length | Certification |
---|---|---|---|---|
PRO10 | 10 GPM Class A | 1¼” x 1” | 22” | NSF-55 A |
Atmospheric Storage Tank Specifications
Model | Capacity | Inlet Connection | Outlet Connection | Manway | Width | Height | Empty Weight | Certification |
---|---|---|---|---|---|---|---|---|
61-TKT03U | 300 Gallons | 1½” Bulkhead NPT | 2” Bulkhead NPT | 16” | 36” | 81” | 80 lbs. | FDA 21CFR 177.1520(1) 3.1 and 3.2 |
UPC | 749460856252 |
---|